| 
                         
						
                          |   | 
                         
                        
                            | 
                         
                        
                          |   | 
                         
                        
                          
                         
                          
                            
                              
                                  
                                 
  
      | 
    
  
    |   Name/Model: | 
      Closed-loop Hall current sensor CHB-300SG, 500SG (TG) | 
   
  
    |   Rated input Parameter: | 
      DC, AC or pulsed 300A, 500A current / ¢35mm | 
   
  
  | 
   
 
                         
                          
 
| 
 SENSOR MODULE  CHB-300SG, 500SG (TG)  |  
| 
 The SENSOR Module CHB-300SG, 500SG is a closed loop Hall current sensor to measure 300A…500A DC,   |  
| 
 AC or pulsed currents with a galvanic isolation between the primary and secondary circuits.  |  
| 
    |  
| 
 Closed-loop Hall Current Sensor:  |  
| 
 Type  | 
 Nominal current  | 
 Output current  | 
 Accuracy  | 
 Supply voltage  | 
 Aperture  |  
| 
 IN(A)  | 
 IM(mA)  | 
 X(%)  | 
 Vc(V)  | 
 mm  |  
| 
 CHB-300SG  | 
 300  | 
 150  | 
 ±0.5%  | 
 ±12~18  | 
 ¢35  |  
| 
 CHB-500SG  | 
 500  | 
 100  | 
 ±0.5%  | 
 ±12~18  | 
 ¢35  |  
| 
 CHB-300TG  | 
 300  | 
 150  | 
 ±0.5%  | 
 ±12~18  | 
 Bus bar  |  
| 
 CHB-500TG  | 
 500  | 
 100  | 
 ±0.5%  | 
 ±12~18  | 
 Bus bar  |  
| 
    |  
| 
 Specifications:    |  
| 
 Principle  | 
 Closed loop Hall effect principle  |  
| 
 Input current  | 
 300…500A(DC、AC、Pulsed current)  |  
| 
 Output current  | 
 150mA/100mA  |  
| 
 Turns ratio  | 
 1:2000(300A), 1:5000(500A)  |  
| 
 Frequency  | 
 DC~100KHz  |  
| 
 Accuracy  | 
 ±0.5%  |  
| 
 Response time  | 
 <1μS  |  
| 
 Linearity  | 
 <0.1%  |  
| 
 Supply voltage  | 
 ±12~18V(±5%)  |  
| 
 Consumption  | 
 28mA+IM(Output current)  |  
| 
 Isolation voltage  | 
 Between primary and secondary circuit: 6KV RMS/50Hz/1min.  |  
| 
 Operating temp.  | 
 -25…+85℃  |  
| 
 Mounting on  | 
 Fastening on panel  |  
| 
 Applications  | 
 Power supplies, welding machines, converters, industry auto-control, motor drives,  |  
| 
 For industry  | 
 electronic power system, railways, rectifiers systems etc.  |  
| 
 >>Back  |   
                           
                                
                                 | 
                             
                            
                              |   | 
                             
                            
                            
                            | 
                         
                      
                    |