SENSOR MODULE CHV-6KV~10KV |
|
The SENSOR Module CHV-6KV~20KV is a closed loop Hall voltage sensor to measure 6000V…10,000V DC, AC |
|
or pulsed voltages with a galvanic isolation between the primary and secondary circuits. |
|
|
|
Closed-loop Hall Voltage Sensor: |
|
Type |
Nominal voltage |
Output current |
Accuracy |
Supply voltage |
Connection |
|
VN(V) |
IM(mA) |
X(%) |
Vc(V) |
Input |
|
CHV-6KV |
6000 |
80 |
±0.5% |
±15~24 |
Terminals |
|
CHV-7KV |
7000 |
|
|
|
|
|
CHV-8KV |
8000 |
|
|
|
|
|
CHV-9KV |
9000 |
|
|
|
|
|
CHV-10KV |
10000 |
80 |
±0.5% |
±15~24 |
Terminals |
|
|
|
|
|
|
|
|
|
|
Specifications: |
|
Principle |
Closed loop Hall effect principle |
|
Input voltage |
6000…10,000V (DC、AC、Pulsed voltage) |
|
Output current |
80mA |
|
Frequency |
—— |
|
Accuracy |
±0.5% |
|
Response time |
500μS |
|
Linearity |
0.1% |
|
Supply voltage |
±15~24V(±5%) |
|
Consumption |
80mA+IM(Output current) |
|
Isolation voltage |
Between primary and secondary circuit: 15KV~25KV RMS/50Hz/1min. |
|
Operating temp. |
-25…+70℃ |
|
Mounting on |
Fastening on panel |
|
Applications |
Power supplies, welding machines, converters, industry auto-control, motor drives, |
|
For industry |
electronic power system, railways, rectifiers systems etc. |
|
>>back |