SENSOR MODULE CHV-100/800~3000 (A) |
The SENSOR Module CHV-100/800~4000 is a closed loop Hall voltage sensor to measure 800V…3000V DC, AC |
or pulsed voltages with a galvanic isolation between the primary and secondary circuits. |
|
Closed-loop Hall Voltage Sensor: Output 5V |
Type |
Nominal voltage |
Output voltage |
Accuracy |
Supply voltage |
Connection |
VN(V) |
VM(V) |
X(%) |
Vc(V) |
Input |
CHV-100/800 |
800 |
5 |
±0.5% |
±12~15 |
Terminals |
CHV-100/1000 |
1000 |
|
|
|
|
CHV-100/2000 |
2000 |
|
|
|
|
CHV-100/2500 |
2500 |
5 |
±0.5% |
±12~15 |
Terminals |
CHV-100/3000 |
3000 |
|
|
|
|
|
|
|
|
|
|
Closed-loop Hall Voltage Sensor: Output 25mA |
Type |
Nominal voltage |
Output current |
Accuracy |
Supply voltage |
Connection |
VN(V) |
IM(mA) |
X(%) |
Vc(V) |
Input |
CHV-100/600A |
600 |
25 |
±0.5% |
±12~15 |
Terminals |
CHV-100/1000A |
1000 |
|
|
|
|
CHV-100/2000A |
2000 |
|
|
|
|
CHV-100/2500A |
2500 |
25 |
±0.5% |
±12~15 |
Terminals |
CHV-100/3000A |
3000 |
|
|
|
|
|
|
|
|
|
|
Specifications: |
Principle |
Closed loop Hall effect principle |
Input voltage |
800…3000V (DC、AC、Pulsed voltage) |
Output |
5V/25mA |
Frequency |
DC~20KHz |
Accuracy |
±0.5% |
Response time |
40…200μS |
Linearity |
0.1% |
Supply voltage |
±12~15V(±5%) |
Consumption |
10mA+IM(Output current) |
Isolation voltage |
Between primary and secondary circuit: 6KV RMS/50Hz/1min. |
Operating temp. |
-25…+70℃ |
Mounting on |
Fastening on panel |
Applications |
Power supplies, welding machines, converters, industry auto-control, motor drives, |
For industry |
electronic power system, railways, rectifiers systems etc. |
>>back |