SENSOR MODULE CHV-30VD~600VD |
|
The SENSOR Module CHV-30VD~600VD is a closed loop Hall voltage sensor to measure 30V…600V DC, AC |
|
or pulsed voltages with a galvanic isolation between the primary and secondary circuits. |
|
|
|
Closed-loop Hall Voltage Sensor: |
|
Type |
Nominal voltage |
Output voltage |
Accuracy |
Supply voltage |
Connection |
|
VN(V) |
VM(V) |
X(%) |
Vc(V) |
Input |
|
CHV-30VD |
30 |
5 |
±1.0% |
±12~15 |
Terminals |
|
CHV-100VD |
100 |
|
|
|
|
|
CHV-300VD |
300 |
|
|
|
|
|
CHV-600VD |
600 |
|
|
|
|
|
|
|
Specifications: |
|
Principle |
Closed loop Hall effect principle |
|
Input voltage |
30…600V (DC、AC、Pulsed voltage) |
|
Output voltage |
5V |
|
Turns ratio |
2500:1000 |
|
Frequency |
DC~20KHz |
|
Accuracy |
±1.0% |
|
Response time |
40μS |
|
Linearity |
0.1% |
|
Supply voltage |
±12~15V(±5%) |
|
Consumption |
35mA |
|
Isolation voltage |
Between primary and secondary circuit: 2.5KV RMS/50Hz/1min. |
|
Operating temp. |
-25…+70℃ |
|
Mounting on |
Fastening on panel |
|
Applications |
Power supplies, welding machines, converters, industry auto-control, motor drives, |
|
For industry |
electronic power system, railways, rectifiers systems etc. |
|