Home > Products
 
 
  Name/Model:   Closed-loop Hall voltage sensor CHV-100
  Rated input Parameter:   DC, AC or pulsed 100V~2500V (10mA) voltage
  Download:   Download the manual

SENSOR MODULE  CHV-100

The SENSOR Module CHV-100 is a closed loop Hall voltage sensor to measure 100V…2500V(10mA) DC, AC or

pulsed voltages with a galvanic isolation between the primary and secondary circuits.

 

Closed-loop Hall Voltage Sensor:

Type

Nominal current

Output current

Accuracy

Supply voltage

Connection

INmA

IMmA

X%

VcV

Input

CHV-100

10

50

±1.0%

±12~15

Terminals

 

Specifications: 

Principle

Closed loop Hall effect principle

Input current

10mA(100V…2500V DCACPulsed voltage

Output current

50mA

Turns ratio

10000:2000

Frequency

DC~50KHz

Accuracy

±0.6%

Response time

20…100μS

Linearity

0.1%

Supply voltage

±12~15V±5%

Consumption

10mA+IMOutput current

Isolation voltage

Between primary and secondary circuit: 6KV RMS/50Hz/1min.

Operating temp.

-25…+70

Mounting on

Fastening on panel

Applications

Power supplies, welding machines, converters, industry auto-control, motor drives,

For industry

electronic power system, railways, rectifiers systems etc.

>>back