Name/Model: |
DC current transducer CHZ-*S |
Rated input Parameter: |
DC 5A~300A current / ¢20mm |
|
SENSOR MODULE CHZ-*S |
The SENSOR Module CHZ-*S is a signal conditioning DC current transducer to measure 5A…300A DC current |
with a galvanic isolation between the primary and secondary circuits. |
|
Signal conditioning DC current transducer: |
Type |
Nominal current |
Signal output |
Accuracy |
Supply voltage |
Aperture |
IN(A) |
VM / IM |
X(%) |
Vc(V) |
mm |
CHZ-5S/# |
5 |
A0, A1, V0 |
±0.5% |
+24 |
¢20 |
CHZ-20S/# |
20 |
See table 1 |
|
|
|
CHZ-50S/# |
50 |
|
|
|
|
CHZ-100S/# |
100 |
|
|
|
|
CHZ-200S/# |
200 |
|
|
|
|
CHZ-300S/# |
300 |
|
|
|
|
Note: Type named, such as CHZ-5S/V0 Nominal input current: 0…5A, Signal output: 0…5V |
|
Table 1: # |
A0 |
A1 |
V0 |
|
|
Signal output |
0…20mA |
4…20mA |
0…5V |
DC |
|
|
Specifications: |
Input current |
5…300A (DC current) |
Signal Output |
A0, A1, V0, (See table 1) |
Frequency |
DC |
Accuracy |
±0.5% |
Response time |
<0.35S |
Linearity |
<0.5% |
Supply voltage |
+24V(±5%) |
Consumption |
30mA+IM(Output current) |
Isolation voltage |
Between primary and secondary circuit: 6KV RMS/50Hz/1min. |
Operating temp. |
-25…+85℃ |
Mounting on |
Fastening on panel |
Applications |
Power supplies, industry auto-control, motor drives, electronic power system, railways etc. |
>>Back |
|
|
|
|