Home > Products
 
 
  Name/Model:   AC or DC voltage transducer of ON-OFF output CHY-*VS/K CHZ-*VS/K
  Rated input Parameter:   AC or DC 100V~500V voltage

SENSOR MODULE  CHY-*VS/K  CHZ-*VS/K

The SENSOR Module CHY-*VS/K and CHZ-*VS/K is an ON-OFF output voltage transducer to measure

100V…500V AC or DC voltages with a galvanic isolation between the primary and secondary circuits.

 

ON-OFF output AC voltage transducer:

Type

Nominal voltage

Relay output

Accuracy

Supply voltage

Connection

VNV

@ Input < VN

X%

VcV

Input

CHY-100VS/K1

100

Open

±1.0%

+24

Terminals

CHY-200VS/K1

200

(Relay output)

CHY-300VS/K1

300

(See table 1)

CHY-400VS/K1

400

CHY-500VS/K1

500

 

ON-OFF output DC voltage transducer:

Type

Nominal voltage

Relay output

Accuracy

Supply voltage

Connection

VNV

@ Input < VN

X%

VcV

Input

CHZ-100VS/K1

100

Open

±1.0%

+24

Terminals

CHZ-200VS/K1

200

(Relay output)

CHZ-300VS/K1

300

(See table 1)

CHZ-400VS/K1

400

CHZ-500VS/K1

500

Note: Type named, such as CHZ-100VS/K1

Nominal input voltage: VN = 100V (DC)

Relay output state of K1: Open @ Input<100V (DC),  Close @ Input≥100V (DC)

 

Table 1

K1

On-off state

K3

On-off state

Relay output

Input < VN

Open

Input < VN

Close

Input ≥ VN

Close

Input ≥ VN

Open

 

Specifications: 

Input voltage

100…500V (AC or DC voltage

Relay Output

K1 or K3 (Relay output, See table 1)

Frequency

AC 50Hz (400Hz) or DC

Accuracy

±1.0%

Response time

<0.35S

Supply voltage

+24V±5%

Consumption

30mA (CHY), 90mA (CHZ)

Isolation voltage

Between primary and secondary circuit: 2.5KV RMS/50Hz/1min.

Operating temp.

-25…+85

Mounting on

Fastening on panel

Applications

Power supplies, industry auto-control, motor drives, electronic power system, railways etc.

>>back